How Interface Treatment Works in Ansys Mechanical Contact Analysis

In nonlinear contact analysis, the initial geometric relationship between two surfaces can strongly influence both convergence and the physical meaning of the solution. Before external loading begins, Ansys evaluates the contact pair according to its initial gap or penetration and the contact detection region. A pair that is expected to transmit load but starts open … Continue reading How Interface Treatment Works in Ansys Mechanical Contact Analysis

Contact Analysis of a Pipe-clamp Assembly

We have discussed multiple examples of contact analysis so far. In this post, we are going to investigate a pipe-clamp assembly. By using a pretensioned bolt, the clamp holds the pipe firmly (see the following figure). If the pretension is insufficient, slipping would happen between the pipe and clamp. If the pretension is too large, … Continue reading Contact Analysis of a Pipe-clamp Assembly